GE’s Q.Freeze Motion Correction for PET/CT

GE’s Q.Freeze Motion Correction for PET/CT

Q.Freeze imaging technology virtually eliminates a patient’s respiratory motion within PET/CT imaging, potentially resulting in healthcare cost savings

Digital radiography news WAUKESHA, WI APRIL 18, 2012— GE Healthcare today announced it has received FDA clearance of Q.Freeze, one of the PET/CT quantitative imaging technologies designed to enable treatment evaluation earlier in a patient’s cancer treatment.

Q.Freeze combines the quantitative benefits of 4D phase-matched PET/CT imaging, MotionMatch, into a single static image. By collecting CT and PET data at each phase of the breathing cycle, then matching the data for attenuation correction purposes, Q.Freeze is designed to improve quantitative consistency compared to conventional static PET imaging techniques while facilitating the reading of the 4D PET/CT imaging. None of the acquisition data is wasted, as 100 percent of the counts collected are combined to create a single static image. The goal is an image that has the dual benefit of frozen patient respiratory motion and reduced image noise.

The spark behind the idea—which has been under development since 2006—was correcting for lesion movement tied to respiratory motion at the same comfort and dose level as a routine static procedure would support clinicians’ diagnostic confidence. Because patients may not breathe the same way as they might have during their base line study, Q.Freeze could help enable easy and proper longitudinal response to therapy comparisons.

“GE Healthcare has demonstrated its excellence in addressing one of the biggest clinical challenges in PET/CT: respiratory motion” said Michael Barber, vice president and general manager, Molecular Imaging, GE Healthcare. “Respiratory motion impacts image clarity and quantification accuracy of lesions in organs subject to respiratory motion such as the lung, liver and pancreas. Now with Q.Freeze, GE Healthcare is offering an innovative technology that makes patient respiratory motion correction a routine procedure for every scan.”

In a recent study by Professor Cristina Messa, Head of the Nuclear Medicine Department and Dr. Luca Guerra, Nuclear Medicine Physician of The Center for Molecular Bio-imaging and San Gerado Hospital (HSG-CBM), a patient underwent PET/CT for nodule characterization. Their findings included a comparison of static acquisition, 4D PET/CT acquisition and Q.Freeze acquisition to determine clear evidence of a metabolic lesion. The Q.Freeze acquisition was able to increase the image quality making the lesion easily identifiable. According to the doctors, this improvement leads to a potential workflow benefit allowing the physician to review only one set of images free of a patient’s respiratory motion.

Q.Freeze is included in the GE Healthcare Q.Suite*, a collection of next-generation capabilities designed to further quantitative PET by generating more consistent Standardized Uptake Value (SUV) readings — enabling clinicians to assess treatment response accurately. During the course of cancer treatment, clinicians traditionally gauge progress by looking for physical change in the size of a tumor, typically using Computed Tomography (CT) or Magnetic Resonance (MR). However, with quantitative PET imaging, they are also able to consider a tumor’s metabolic activity. In many cases, metabolic changes in a tumor can be perceived earlier than physical ones, thus quantitative PET can give physicians an earlier view of how well a treatment is working.

For quantitative PET to be effective, consistency of SUV measurements between a patient’s baseline scan and subsequent follow-up scans is critical. Variation can occur throughout the PET workflow, in areas from patient management and biology to equipment protocols and performance. Controlling these variables to increase consistency can improve the clinician’s confidence that an SUV change has true clinical meaning.

“Doctors are seeking quantitative tools, such as Q.Freeze, to obtain reproducible measurements over a longitudinal patient study. Q.Freeze is one of the first element of a suite of tools that may enable doctors to assess confidently biological changes in a patient during a course of treatment, allowing them to quickly and accurately modify treatment regimens, “said Vivek Bhatt, general manager, PET/CT, GE Healthcare. “These tools, ultimately, could potentially contribute to personalized oncology care, increase quality of patient care and reduce wasted expenditure on ineffective treatment.”

About GE Healthcare

GE Healthcare provides transformational medical technologies and services that are shaping a new age of patient care. Our broad expertise in medical imaging and information technologies, medical diagnostics, patient monitoring systems, drug discovery, biopharmaceutical manufacturing technologies, performance improvement and performance solutions services help our customers to deliver better care to more people around the world at a lower cost. In addition, we partner with healthcare leaders, striving to leverage the global policy change necessary to implement a successful shift to sustainable healthcare systems.

Our “healthymagination” vision for the future invites the world to join us on our journey as we continuously develop innovations focused on reducing costs, increasing access and improving quality around the world. Headquartered in the United Kingdom, GE Healthcare is a unit of General Electric Company (NYSE: GE). Worldwide, GE Healthcare employees are committed to serving healthcare professionals and their patients in more than 100 countries. For more information about GE Healthcare, visit our website at www.gehealthcare.com.

GE Healthcare received FDA clearance for its Q.Freeze motion correction technology that combines multiple PET/CT images from different points in the patient’s respiratory cycle to create a composite high resolution image.

This is accomplished thanks to a camera that tracks the movement of a block resting on the patient’s chest, which provides movement correction data to the algorithm that’s aggregating the images together.

Q.Freeze combines the quantitative benefits of 4D phase-matched PET/ imaging, MotionMatch, into a single static image. By collecting CT and PET data at each phase of the breathing cycle, then matching the data for attenuation correction purposes, Q.Freeze is designed to improve quantitative consistency compared to conventional static PET imaging techniques while facilitating the reading of the 4D PET/CT imaging. None of the acquisition data is wasted, as 100 percent of the counts collected are combined to create a single static image. The goal is an image that has the dual benefit of frozen patient respiratory motion and reduced image noise.

Source : http://www.healthimaginghub.com/126-medical-imaging/

www.3732-ge-healthcare-receives-fda-clearance-of-q-freeze-helps-clinicians-assess-cancer-treatment-response.html

Related Posts Plugin for WordPress, Blogger...
Be Sociable, Share!

About the Author

has written 1822 posts on this blog.

Copyright © 2017 Medical Technology & Gadgets Blog MedicalBuy.net. All rights reserved.
Proudly powered by WordPress. Developed by Deluxe Themes