Aptus Endosystems Receives FDA Clearance for Thoracic-Length HeliFX Aortic Securement System

Aptus Endosystems Receives FDA Clearance for Thoracic-Length HeliFX Aortic Securement System

Sunnyvale, CA, September 18, 2012—Aptus Endosystems, Inc., a medical device company developing advanced technology for endovascular aneurysm repair (EVAR), announced today that it received 510(k) clearance from the U.S. Food and Drug Administration (FDA) for its thoracic-length HeliFX™ Aortic Securement System. Similar to the original HeliFX system that was cleared in November 2011 and designed for treating abdominal aortic aneurysms (AAA), the new system consists of a longer delivery device with additional tip configurations to bring the innovative helical EndoAnchor™ technology to the treatment of thoracic aortic aneurysms (TAA).

Aortic aneurysms are an enlarged and weakened section of the aorta, the main artery carrying blood from the heart, which can be lethal if left untreated. It is estimated that 60,000 people in the U.S. may have a TAA. In thoracic endovascular aneurysm repair (TEVAR), an alternative to open surgical repair of TAA, a minimally invasive catheter-based system is used to implant a metal and fabric endograft to isolate blood flow away from the aneurysm to prevent potential rupture and death. Complications can arise from TEVAR if the implanted endograft migrates (loses position) or does not result in a seal with the vessel wall (endoleak) to effectively isolate the aneurysm.

The new HeliFX System allows physicians to deliver Aptus’ novel EndoAnchor technology to the thoracic aortic anatomy. The implantable EndoAnchor enables independent endograft fixation, and is designed to replicate the sealing and fixation of hand suturing performed during open surgical repair of aortic aneurysms. It can be used during de novo (initial) TEVAR procedures to enhance an endograft’s inherent fixation and sealing mechanisms. In addition, the EndoAnchors can be used to repair endovascular grafts that have migrated away from the implant site and have developed endoleaks or are at risk of developing these complications. In such cases, augmented fixation and/or sealing is required to regain or maintain effective aneurysm exclusion.

“Complications from TEVAR such as endograft migration and endoleaks are even more critical in this patient population given the high surgical morbidity and mortality rates,” said Michael Dake, M.D., Professor of Cardiothoracic Surgery at Stanford University School of Medicine, Stanford, Calif. “The HeliFX system offers physicians a new endovascular capability to improve fixation and sealing of TEVAR endografts and potentially improve procedural durability for patients.”

“The demonstrated capabilities of HeliFX for infrarenal EVAR in duplicating the strength of a hand-sutured aortic anastomosis will be even more valuable in the challenging environment of the thoracic aorta,” said David Deaton, M.D., Associate Professor of Surgery and Chief of Vascular and Endovascular Surgery at Georgetown University Hospital, Washington, D.C. “The TAA HeliFX will allow surgeons greater control over the fixation and positioning of TEVAR devices and has promise for significantly reducing the susceptibility of TEVAR to the devastating consequences of late failure resulting from migration or aortic dilatation.”

“The FDA clearance of our new HeliFX System is a major milestone for Aptus and a significant technological advancement in the field of TEVAR,” said James Reinstein, CEO of Aptus Endosystems. “Given our initial success in helping AAA patients with our EndoAnchor technology, we are excited to provide patients with TAA a viable treatment option to address the potential problems associated with TEVAR.”

Clearance of the new HeliFX System in the U.S. allows the device to be used with Cook Medical’s Zenith® TX2®, W.L. Gore’s TAG®, and Medtronic’s Talent® Thoracic and Valiant® endografts in both initial implant and secondary repair settings. Use with other endografts has not been evaluated to date.

About Aptus Endosystems, Inc.

Headquartered in Sunnyvale, Calif., Aptus Endosystems is a privately held medical device company focused on developing advanced technology for endovascular aneurysm repair (EVAR). An estimated 1.5 million Americans have an abdominal aortic aneurysm (AAA), which can be life-threatening if left untreated and approximately 200,000 people are newly diagnosed each year. Aptus Endosystems has developed a unique endograft and innovative helical anchor technology that allows physicians to perform minimally invasive EVAR while still providing the control and potential long term durability of an open surgical repair. The Fortevo™ AAA Endograft System and the HeliFX™ Aortic Securement System bear the CE Mark for distribution in the European Union. The HeliFX Aortic Securement System is cleared by the FDA for distribution in the United States. The Fortevo AAA Endograft System is Investigational Use Only in the United States. For more information, please visit www.aptusendosystems.com.

Aptus Endosystems has received CE Mark approval for its Aptus EndoStapling System for use in endovascular aneurysm repair (EVAR) procedures. EVAR procedures are performed to treat abdominal aortic aneurysms and are performed more and more often instead of open surgical repair. Proximally, the stent is fixated to the aortic wall to avoid migration and endoleaks. During open procedures, this is done by meticulously suturing, however during endovascular procedures only the stent’s self-fixating property prevents these complications.

The EndoStapling System uses a helical staple technology for independent endograft fixation, mimicking the hand suturing performed during open surgical repair. It can be used to repair endovascular grafts that have migrated or exhibit endoleaks, by strengthening the radial fixation and/or sealing to regain or maintain effective aortic aneurysm exclusion. It can also be used at the time of initial endograft implantation to enhance an endograft’s inherent fixation and sealing mechanisms. From the press release:

“The use of the Aptus EndoStapling system will be a great advantage to simplify revision surgery for migrated endografts,” said Jean Paul de Vries, M.D., Ph.D., Head of the Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands. “The ability to staple migrated endografts to the aortic wall and to fixate extension cuffs will overcome most migrations and type IA endoleaks. This system truly mimics a sutured anastomosis.” In addition, de Vries said, “EndoStaples can improve fixation of de novo endografts in challenging proximal necks – short, large and angulated – and can potentially reduce distal migration during follow-up.”

AptusEndoStaple1 Aptus EndoStapling System Receives CE ApprovalAptus Endosystems CEO Jeff Elkins called the CE Mark approval a “significant milestone.” He went on to comment that, “Given the recent publication of several long term EVAR outcome studies, we now recognize that late EVAR failure and the need for secondary intervention is a major underserved clinical need affecting many patients, and continued improvement in technology is required. To date, physicians have had limited prophylactic and treatment options for graft migration and Type I endoleaks. The novel concept of independent and physician controlled proximal fixation using the EndoStapling System is a considerable step toward addressing long term complications and making EVAR a more definitive solution for treating aortic aneurysms.”

The EndoStapling system is approved for use with Aptus’ own endograft and with the Cook Zenith, Gore Excluder, and Medtronic AneuRx, Endurant, and Talent endografts in both initial implant and secondary repair settings. In an initial phase I trial with 21 patients, no device migration and no Type I, III, or IV endoleaks were detected one year after implantation. A larger follow-up trial with 155 patients is currently underway, of which we anxiously await the results.

Securing Stability for your Endografts

To address the challenges of fixation and sealing, the HeliFX™ Aortic Securement System is designed to bring the stability of a surgical anastomosis to endovascular aneurysm repair (EVAR). The helical EndoAnchors™ provide independent transmural fixation to the aortic wall to enhance the inherent sealing and fixation of leading endografts.

Enhanced Sealing and Fixation with a Stand-Alone System

Stabilizing Endograft Fixation and Seal

EndoAnchor transmural fixation provides the stability of a surgical anastomosis

Endograft fixation tailored to patient’s anatomy intraoperatively

Ideal for de novo or secondary repair procedures

Compatible with leading AAA endografts

HeliFX Endoanchor

(click to enlarge)

Ease of Implantation

Motorized controls for two-stage EndoAnchor deployment with repositioning

Highly visible components aid in precise placement

Intuitive delivery steps for ease of use

Low profile 16 Fr OD implantation system

HeliFX System

(click to enlarge)

Durable Results

Achieves the strength of a surgical anastomosis

Maintains effective seal and aneurysm exclusion

Superior migration prevention

Confidence for complex anatomy

Source : http://www.aptusendosystems.com/news/2012/091812.html